Why is my Onan generator light blinking?

The genset controller provides extensive diagnos- tics by causing the status indicator light on the Con- trol Switch to blink in a coded fashion. Following a fault shutdown, the indicator light will repeatedly blink 2, 3 or 4 blinks at a time. Two blinks indicates a low oil pressure fault.

How do I clear the code on my Onan generator?

How to Clear a Fault Code on Onan Generator

  1. Locate the primer button on the generator.
  2. Hold the primer button down for at least 30 seconds.
  3. Release the button and start the generator.
  4. Allow the generator to run for 15 minutes, to ensure that the code has cleared.

Why does my Onan generator shut off?

1. Check the oil level in your generator when the oil level gets low it will shut down the generator. As the oil gets warmer it thins out just enough that it may fall below the proper level and shutdown the generator. Check the fuel filter for the generator as it may be restricting the amount of fuel getting to it.

What does it mean when your Onan generator flashes 3 times?

Just remember to not over-fill your oil tank. Too much oil is not a good thing When you see this code, it indicates that there is a problem somewhere on your Onan generator. You will get 3 flashes then a pause, then 3 flashes, then a pause and on it goes till you press the button to get the secondary code.

Is there a fault code on an Onan generator?

A generator is the primary source of power for RVs, so taking care of yours is imperative to an enjoyable RV experience. Any kind of fault code is alarming at first, but fault code 14 on an Onan Generator is one of the easiest to remedy on your own, in most cases.

Why do I need to exercise my Onan generator?

The reason you need to exercise your Onan generator is that the carb can get what is called varnish build-up. This build-up gums up the carb and has it running at inefficient levels. Keeping your carb clean is vital to a smooth operating generator. You may see your Onan generator blink 3 times then stop then blink 3 more times.

When to take Onan generator to certified Onan dealer?

When you confirm the 31 code, you need to take the generator to the certified Onan dealer to get it fixed Code 32 – Low Cranking Speed This code informs you that your cranking speed is below 180 rpms for 2 seconds.

Just remember to not over-fill your oil tank. Too much oil is not a good thing When you see this code, it indicates that there is a problem somewhere on your Onan generator. You will get 3 flashes then a pause, then 3 flashes, then a pause and on it goes till you press the button to get the secondary code.

What does the code on the Onan generator mean?

When you see this code, it indicates that there is a problem somewhere on your Onan generator. You will get 3 flashes then a pause, then 3 flashes, then a pause and on it goes till you press the button to get the secondary code. The secondary code will give you the specific problem that is wrong with your generator.

What to do if your generator has a blink code?

Turn the generator off and wait for at least 2 minutes before restarting. The governor has one wire to the controller and one wire for ground. If either one is loose, that will trigger this code. All you have to do is tighten the loose wire and you should be good to go.